Overview

Up to 4 channels of galvanic corrosion current can be measured, and high sampling measurement is realized by converting the output to voltage.

Product type

Zero Resistance Ammeter

  • Measure galvanic corrosion current
  • Up to 4ch can be connected

If you have any questions,
please feel free to contact us.

Specification

Channel

4 channels ※Can be expanded


Current Range

Any 3 ranges can be specified per channel (Example: 10μA, 100μA, 2mA)

Maximum Range 10mA (Optional 100mA) Manual range switching


Frequency Characteristics

If not specified, 50Hz -3dB (optimal for 10Hz measurement)


Input Channel

Independent 4ch(4 Circuits)


Input/Output Conversion Ratio

1 V for current range full scale, or specified voltage


Input/Output Impedance

10Ω(typ)


Power

DC9V~12V


Weight

App. 0.75kg


Size

170mm(W)×120mm(D)×70mm(H)(Excluding Protrusions and Cables)


Option

BNC cable

  • BNC cable for output

If you have any questions,
please feel free to contact us.